Set Up the Tester
15
Reflector Configuration (LR-AT 2000 Model)
This screen is used to configure the LR-AT 2000 for remote
access to Fluke Networks EtherScope Network Assistant,
MetroScope Service Provider, and OptiView Analyzer’s
throughput performance tests.
Note
The LR-AT 2000 can reflect jumbo frame sizes up to
9600 bytes.
Select Tools > Reflector. The default or pre-configured
Reflector settings are displayed below
ffy32.bmp
Figure 12. Reflector Settings Screen
Select Configure.
ffy33.bmp
Figure 13. Reflector Default Configuration Screen
The LR-AT 2000 must be configured to:
MAC + Fluke - This filter setting allows the LR-AT 2000 to
only reflect packets when the destination MAC address
field matches the LR-AT 2000's own MAC address and Fluke
payload.
MAC + IP - This swap setting allows the LR-AT 2000 to swap
the source and destination MAC and IP addresses for
packets that are reflected back to the analyzer.